Sterilwave 100
The Sterilwave 100 is particularly suited to medical facilities generating only small amounts of waste. This biomedical waste management system can treat up to 20kg of waste per hour*. Sterilwave 100 is ultra-compact and comes in a mobile version, for use in a container for example.
SPECIFICATIONS STERILWAVE 100
- 8log 10 Microbiological inactivation
- Efficient heating through industrial microwave technology (110 degrees)
- No use of steam for the sterilisation process
- No steam pressure before, during and after processing No radiation risks
- No risk of explosion
- Applicable for any kind of medical waste (needles, glass, plastic, liquid)
- No waste separation required
- Easy to maintain and low cost
- Easy to operate
- The final product is unrecognizable, dry, stable waste
- Complies with all international standards, including STAATT NFX30-503
- Waste Capacity (Density 1 L = 0.100 kg): up to 20 Kilograms per hour
- Technology: Grinding by rotating blades. heating by microwave
- Bacterial inactivation: Spore > 8log10 Virus > 6log10
- Waste Volume reduction: Up to 80%
- Waste Weight reduction: Up to 25%
- Final Waste: Unrecognizable, inert, dry, stable, Refuse Derived Fuel
- Loading Process: Manual
- Average cycle time:30 minutes
- Tank volume: 100 Liters
- Dimensions (L x W x D): 1 x 1 x 1 Meters
- Weight: 800 Kilograms
- Electricity: 400V/ 3-Phase, 63A 8
- Electrical consumption: 8 – 10 kw per hour
- Recommended floor space: 8 Square Feet
- Recommended Ceiling height: 2 Meter